Steel Roof Cladding Minimum Pitch
The following table provides the minimum required allowable roof slope for each type of roofing material mentioned in the code.
Steel roof cladding minimum pitch. Concealed fix kliplok roof profile available materials. The profile sheets are typically coated steel but can. Concealed fix minimum roof pitch. The lower run is the primary weather seal and should be positioned as close as possible to the edge of the top sheet.
The minimum roof slope allowed by code for any type of roof is in 12 applicable only to coal tar pitch roof systems. The minimum slope for lapped non soldered seam metal roofs without applied lap sealant shall be three units vertical in 12 units horizontal 25 percent slope. The pitch is measured in inches of vertical rise per foot of horizontal run and the 5v crimp profile shown above requires a minimum slope of three in twelve or 3 12 3 inches vertically per 12 inches horizontally. Galvanised steel steel with chromadek coating.
Fixings secret fixed lug system for long sheet lengths. The standard of lower pitch actually ranges between 1 12 to 5 12. Anything above that will require you to put out higher cost because they are already considered as higher pitch. 2 degrees if there are no penetrations in the concealed fix roof system or 7 5 degrees is there are any vents or penetrations in the roof system.
Panels joined with an applied lap sealant can go as low as 12. In fact the larger the first number becomes the steeper the slope. The minimum pitch is typically 3 12 meaning the roof should rise 3 inches for every 12 inches of horizontal foot. Corrugated metal roofing has the same minimum pitch.
The profile is made up of a series of corrugations each in the shape of a trapezium refered to as trapezoidal profile which lap together side to side and end to end making it very easy to cover varying areas of roof quickly. Orientation roofing and vertically laid cladding. The pitch of a roof is expressed in a ratio of rise over run creating a theoretical triangle with these numbers to illustrate the amount of slope. The standard end lap arrangement for trapezoidal steel weather sheets at any roof pitch greater than or equal to 4 is shown in fig 12.
Trapezoidal profile roof sheets. Profiled roof systems are best suited for roof pitches greater than 5 degrees. The minimum pitch for metal roof shingles and lapped non soldered panels is 3 12. Resin coated zincalume zincalume with colorbond coating.
The minimum slope for lapped non soldered seam metal roofs with applied lap sealant shall be one half unit vertical in 12 units horizontal 4 percent slope.