Spray Foam Under Roof
Polyurethane or polystyrene spray foams can provide thorough coverage to roof rafters and attic walls in much less time than is needed for other materials.
Spray foam under roof. Where wood shingles or shakes. I have not heard of any evidence to support your theory. This is a great question. Unlike solid insulation products that require careful measurement cutting and fitting spray foam can cover even the most uneven surface instantly.
How spray foam should be installed on the underside of the roof decking the unvented attic space is completely within the building s thermal envelope. The usual application of spray foam is to repair and re invigorate an existing roof by removing the saturated areas replacing with like materials and then spraying foam over top of the entire roof. Lstiburek takes blame for bad language. Both open cell and closed cell spray foam insulation adhears extremely well to the underside of roof decks and the rafters surrounding them when installed correctly.
Metal roofing manufacturers typically extend a 25 year warranty. Most unvented attics incorporate spray polyurethane foam spf on the underside of the roof deck and attic walls. Moisture generated indoors or that infiltrates into the home is responsible for the bulk of the moisture in an attic insulated with spray foam on the underside of the roof sheathing. It s not coming from above the roof and it s not some new moisture source resulting from the spray foam.
No interior class i vapor retarders e g plastic sheeting are installed on the ceiling side attic floor of the. The concern of manufacturer mbci is over who is going to verify that the foam will not cause corrosive damage over time to the roofing. Open cell spray polyurethane foam ocspf and closed cell spray polyurethane foam ccspf insulation sprayed to the underside of roof sheathing is a popular strategy for increasing roof insulation levels in all climate zones. Spray polyurethane foam roofing or spray foam roofing is a material that s sprayed as a liquid so it can expand into a foam creating a solid layer across an existing roof.
Polyurethane spray foam metal roof insulation in order to add moisture barrier under metal roof you can spray the undersides of the roof by using a thick layer of polyurethane spray foam. This construction approach was first used in the 1970s and it has been implemented much more widely since it was first included in the international code council s icc model building code in 2007 irc section 806 4.